Easy Glucose Measurement

Intuitive biosensor solution for fast and reliable glucose analysis across diverse applications — from fruit juices to chocolate products.

Key Features

Accurate

Accurate results due to highly selective and sensitive enzyme technology.

Easy

No chemical expertise necessary.

Fast

Measuring time 2 minutes.

Versatile

Measure in the lab or in the production environment.

System Components

Biosensor

Reader

PC Software

Support

Biosensor

Immobilized enzymes on the sensor surface catalyze the oxidation of target molecules. Single-use strips, factory calibrated.

Why choose DirectSens® Glucose Biosensor Kit?

HPLC

Requires high capital investment and specialized expertise. Typically suited for large laboratories with high sample throughput.

Enzymatic test kits

Multi-step procedure requiring more than 14 minutes. Measurement accuracy can be affected by gas bubbles, turbidity, or colored ingredients.

Density / Refractive Index

Applicable only to simple matrices containing a single sugar species.

DirectSens® Advantage

Reliable Efficiency

Low investment, streamlined workflow, and accurate results in approximately 2 minutes. Enable faster process decisions, reduce operational costs, and obtain reliable data you can trust.

Traditional Kits 14+ min
DirectSens® 2 min
Get the Kit
3 Simple Steps Process

3 Simple Steps

Streamlined workflow designed for efficiency. No calibration required, no complex cleaning protocols.

Step 01

Dilute

Select the appropriate dilution based on the expected concentration range and mix the sample with buffer.

Step 02

Scan

Instantly transfer all necessary calibration constants and parameters via a quick QR code scan.

Step 03

Measure

Apply 100 µl of sample to the biosensor and obtain precise results in approximately 50 seconds.

Multiparameter System

We designed our biosensor system for multiparameter capability. The variety of available sensor types will continuously increase over the next years.

Now

Available

  • OatSens®
  • Maltose & Glucose
  • Glucose
2026

Coming Soon

  • Alcohol
  • L-Lactate
2027

Development

  • Fructose
  • Sucrose

Future

Additional parameters will be introduced based on customer needs and emerging biosensor technologies.

Products

Glucose Biosensor Kit

DirectSens®

Glucose Biosensor Kit

Measuring Range

Glucose: 5 – 375 g/L

Applications

Chocolate fondant, beer wort, vegan drinks, bread.

Included

25 biosensors, factory calibrated
5 ml buffer
2 ml control solution (glucose)
User manual
Quality assurance certificate
Technical service
Reader T4 Kit

DirectSens®

Reader T4 Kit

Device Type

Handheld (battery)

Housing

Robust aluminum

Features

Touch screen
Intuitive software
Multi parameter capability
Integrated QR code scanner
USB / BT data exchange

Included

Reader
USB A/C cable
Calibration Device (LM10)
Spare front adapter
Manuals (on USB flash drive)
DirectSens® PC software
Carrying hard case

Got Questions?

We've got the answers

Contact us today, and our team will be happy to assist you with personalized support.

Technical Details

The intuitive software guides users step-by-step through a simple measurement workflow. After brief training in pipetting and measurement handling, anyone can operate the system confidently — no chemical background required. Sensors arrive factory-calibrated, eliminating time-consuming calibration procedures.
Optical measurement techniques typically require centrifugation or filtration when samples are turbid, adding processing time and increasing the risk of handling errors. In addition, colored sample components can interfere with optical signals and compromise measurement accuracy. The DirectSens® system combines enzyme specificity with robust electrochemical detection, enabling precise and reliable glucose quantification directly in turbid or colored samples — without sample preparation. Our technology streamlines analysis also in protein-rich or fat-containing samples, eliminating the need for Carrez clarification or fat separation steps.
No laboratory environment or specialized personnel are required. Measurements can be performed wherever space is available for dilution and testing, provided the ambient temperature is between 20–24 °C (68–75 °F). This enables faster process control and eliminates sample transport delays. .
The measurement takes about two minutes — delivering rapid insights for real-time decision making.
Each system includes everything required for reliable, traceable performance verification with electronic reporting:
  • Measurement Performance Check: Every DirectSens® Biosensor Kit includes a Control Solution for QC validation.
  • Reader Performance Check:The reader kit includes an electronic Testing Device for a quick functionality check-up (approx. 3 minutes).
  • The reader requires no routine maintenance. If liquid enters the biosensor slot, the front module can be replaced easily with a simple one-screw exchange.
    Measurement data can be exported as XLS, CSV, and PDF reports. CSV format enables direct import into LIMS environments for streamlined documentation and compliance workflows.
    Directly sync results with your existing Laboratory Information Management System via secure API.
    Compact dimensions (21x15cm) save valuable bench space in crowded laboratory environments.
    IP65-rated housing protects internal electronics from dust, moisture, and accidental impacts.
    24/7 access to our global team of application specialists and technical engineers.
    Fully compliant with ISO 9001 and CE marking requirements for industrial instrumentation.
    Significant reduction in per-test costs compared to traditional laboratory outsourcing.

    Creamy Fondant Fillings in Chocolate and Sugar Confectionery

    In the chocolate and sugar-confectionery industry, creamy fondant fillings are produced from a firm sucrose paste that becomes soft over time through the action of invertase. After chocolate coating, the enzyme gradually converts sucrose into glucose and fructose, creating the desired smooth texture.

    The DirectSens® Glucose Biosensor Kit enables accurate on-site measurement directly in the production environment. Samples no longer need to be transported to a laboratory.

    Key Advantages:

    Reliable texture control
    On-site measurements
    Consistent batch quality

    Invert Sugar Production

    Invert sugar is produced through enzymatic or acid-catalyzed conversion of sucrose into glucose and fructose. For process optimization and consistent quality control an accurate monitoring of glucose concentration is needed.

    The DirectSens® Glucose Biosensor Kit provides immediate on-site process control without the need for laboratory infrastructure.

    Key Advantages:

    Precise process control
    Directly at the production site
    No chemical expertise required

    Brewing non-alcoholic beer

    When producing alcohol-free beer using maltose-negative yeast strains, precise control of fermentation parameters is essential. Monitoring glucose concentration helps to forecast the final alcohol concentration.

    The DirectSens® Glucose Biosensor Kit enables fast, reliable measurements directly in the brewery environment.

    Key Advantages:

    Precise glucose results
    Rapid on-site measurements
    Full process control

    Free Validation Service

    You want to test the DirectSens® Glucose Biosensor Kit? Just send us some samples to analyze and then compare with your reference results. We offer three analyses per customer free of charge.

    The DirectSens® Glucose Biosensor Kit enables fast, reliable measurements directly in the brewery environment.

    Measurement

    Verified sample matricesJuice, fruit preps, invert sugar, ketchup, chocolates
    Measuring range glucose5 – 375 g/L
    Repeatability st. dev. glucose< 6 %
    Measuring time50 sec.
    Minimum sample amount100 µL
    Sample and ambient temperature20 – 24 °C (68 – 75 °F)
    Measuring principleElectrochemical biosensor
    Environmental / safety hazardsAll chemicals are water based, nontoxic, nonflammable
    Shelf life of biosensors, buffer and positive control12 months at 2 – 8 °C (36 – 46 °F)

    Electrochemical Reader T4

    Dimensions125 x 65 x 32 mm (4.92 x 2.56 x 1.26 in)
    HousingAnodized aluminum with rubber sleeve
    Weight407 g
    Display58 x 44 mm (2.28 x 1.73 in) touch screen
    BatteryLi-Ion rechargeable, ≈ 7 hrs. lifetime
    Data interfacesUSB C, Bluetooth

    PC / Software

    PC requirements • Windows 10 or 11
    • 25 MB free hard disk space
    • 1 × free USB A port
    Output file formats • XLS
    • CSV
    • PDF

    Additionally Required Materials

    Eppendorfer vials, precision pipettes, pipette tips
    For carbonated samples: Degassing equipment
    Laptop or PC (specifications above)

    Got Questions?

    Scroll

    We've got the answers!

    Contact us today, and our team will be happy to assist you with personalized support.

    Contact Us